<LOGO>
FM Transmitter Measurement Report
Created: 2026-04-30 23-26-17
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.20 MHz 5/5, 52 dBuV YLEX
Pilot RDS Phase Difference
7.2 kHz 2.2 kHz 71 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 64 kHz 19232 0,7332
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
-1,7 dBr 2,71 dBr 5,3 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" YLEX " 6202 10 (Pop M) 0 1 1 1 23:26, 30.04.2026
RT
"YleX Aamu: P "
AF EON
91.5, 91.8, 91.9, 92.6, 93.2, 94.3, 96.1 MHz 6207, 6205, 6201, 6203
FM Scope Max at: 64 kHz MIN: 9 kHz % above 76 kHz: 0,7332 Acquired: 2026/04/30 23.25.12 Total samples: 19232 Equivalent time: 0:16:01 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500